Metadatos de indexación

Estudio Normativo del Electroretinograma a Patrón


 
Dublin Core Elementos de metadatos PKP Metadatos para el documento
 
1. Título Título del documento Estudio Normativo del Electroretinograma a Patrón
 
2. Creador/a Nombre de autor/a, institución, país Rafael Castells Ferras; ICO Pando Ferrer; Cuba
 
2. Creador/a Nombre de autor/a, institución, país Yahumara Alberto Escobar; ICO Pando Ferrer; Cuba
 
2. Creador/a Nombre de autor/a, institución, país Melissa Medina Pastrana; ICO Pando Ferrer; Cuba
 
2. Creador/a Nombre de autor/a, institución, país Ingrid Machado Forzate; ICO Pando Ferrer; Cuba
 
2. Creador/a Nombre de autor/a, institución, país Rene Llanes Rodríguez; ICO Pando Ferrer; Cuba
 
3. Materia Disciplina(s)
 
3. Materia Palabra/s clave electroretinograma; latencia; amplitud
 
4. Descripción Resumen

El Electroretinograma a patrón (pERG) consiste en la medición de la respuesta retiniana central ante un estímulo estructurado, generalmente un damero de luminancia constante que alterna blanco y negro. Además permite la diferenciación electrofisiológica entre maculopatías y neuropatías y facilita la interpretación de los potenciales evocados visuales. En nuestra investigación hemos tomado una muestra inicial de 16 individuos sanos para realizarle el estudio y obtener los patrones de comparación de los componentes registrados en el examen para una correcta obtención de los valores clínicos que puedan arrojar un diagnostico. Se empleo el equipo de electrofisiología visual de la Roland Consult en el laboratorio del Instituto Cubano de Oftalmología Previo al estudio se le realizo a cada paciente un estudio psicofísico de la visión para descartar la presencia de patologías enmascaradas, además se procedió bajo el consentimiento informado del paciente. No se evidenciaron diferencias entre sexos, las latencias de N35 y N95 fueron las más variables mientras que la  P50  la más estable.

ABSTRACT

The Pattern Electroretinogram ( pERG ) is the retinal answer's measurement central retina  from a  structured stimulus, generally a damero of constant luminance that mixes in black and white. Besides permit electrophysiology differentiation among maculophatíes and neuropathies and make easy the visual evoked potentials interpretation. We have selected a sample initial of 16 healthy individuals In our investigation to accomplish study to him and to obtain the comparison patterns of the registered components in the exam in order to correct clinical values obtaining that they may obtain a diagnosis. Use the visual- electrophysiology team of her Roland Consult in the laboratory of Cuban Ophthalmology Institute. Before study, all  patients was  studies to discard the masked- pathologies presence, besides the consent once  the patient was  given information about proceeded  itself softly. Not differences among sexes, N35's and N95's latencies was a most variables, and P50 was stable always

KeyWords: Electroretinogram, latency, amplitude

 
5. Editorial Institución organizadora, ubicación Facultad de Tecnología de la Salud
 
6. Colaborador/a Patrocinador(es)
 
7. Fecha (DD-MM-AAAA) 2015-04-06
 
8. Tipo Estado y género Artículo revisado por pares
 
8. Tipo Tipo
 
9. Formato Formato de archivo HTML, PDF
 
10. Identificador Identificador uniforme de recursos http://revtecnologia.sld.cu/index.php/tec/article/view/245
 
11. Fuente Título; vol., núm. (año) Revista Cubana de Tecnología de la Salud; Volumen 6, Número 1 (2015): enero - abril
 
12. Idioma Español=es es
 
13. Relación Archivos complementarios
 
14. Cobertura Localización geoespacial, periodo cronológico, muestra de investigación (sexo, edad, etc.)
 
15. Derechos Derechos de autor/a y permisos Copyright (c) 2015 Revista Cubana de Tecnología de la Salud
Licencia de Creative Commons
Este obra está bajo una licencia de Creative Commons Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional.